Security and low voltage

Fire alarm systems

New systems, renovations and panel replacements, installed to code and verified before occupancy.

CommercialIndustrial

Fire alarm installation, extensions and panel replacements for Edmonton commercial, industrial and multi-family buildings, coordinated with permits and verification.

When you need us

Most fire alarm work happens at a few predictable moments: a new building, a tenant improvement that moves walls, a change of use, or an aging panel that can no longer get parts. Each of these changes how the system must be laid out and tested.

  • New construction and additions
  • Tenant improvements that add rooms or change ceilings
  • Change of occupancy, such as office to assembly
  • Panel replacements and system modernization
  • Deficiencies listed on an annual inspection report

Even moving one wall can leave a room without the detection or audibility it needs. Planning fire alarm changes with the rest of the tenant improvement avoids failing the final inspection.

FIG 01Alberta Electrical
Two floors with a fire alarm control panel on floor 1, orange circuits running to smoke detectors, heat detectors, pull stations at exits and horn strobes.Fire alarm system riser, two-storey buildingFLOOR 2FLOOR 1FACP+ batteriesannunc.SDSDHDSDpull stnpull station at exithorn/strobededicated circuitinitiating + signal circuits
Riser diagram of a two-storey building fire alarm showing the control panel, annunciator, smoke and heat detectors, pull stations and horn strobes on each floor.

Codes and standards in Alberta

Whether a building needs a fire alarm, and what kind, is set by the Alberta Building Code based on occupancy, size and other factors. The wiring itself follows the Canadian Electrical Code as adopted in Alberta, and installation, verification and ongoing testing follow CAN/ULC standards referenced by the codes.

Requirements vary by building, and the authority having jurisdiction has the final word. We work from the design drawings where there is an engineer of record, and confirm details with the inspector before rough-in.

FIG 02Alberta Electrical
Five boxes in a row: design, permit and plan review, install and wire, verify every device in orange, then report and sign off, with the relevant CAN/ULC standards listed below.From design to occupancyDesign tocode andstandardsPermit andplan reviewInstalland wireVerifyeverydeviceReportand signoffInstallation: CAN/ULC-S524 (as referenced by code)Verification: CAN/ULC-S537Ongoing inspection and testing: CAN/ULC-S536Exact requirements depend on the building and the authority.
Flow chart of a fire alarm project from design and permit through installation, verification of every device and final reporting.

Installation done properly

A fire alarm is only as good as its wiring. We run initiating and signal circuits in the methods the design calls for, keep them separated from other systems, terminate and label every device, and feed the panel from a dedicated, identified circuit with standby batteries sized for the required duration.

Interfaces matter too. Fire alarm systems often release maglocked doors, shut down air handlers and monitor sprinkler flow and valves. We test each interface so it works in a real alarm, not just on paper.

Where work happens in an occupied building, we tell the monitoring company and building management before any device is isolated, keep the isolation as short as practical, and restore and test before leaving each day. Nothing is left in bypass overnight without the owner and the authority knowing about it.

SafetyNever disable a device

Covering a smoke detector during renovation or unplugging a horn because it is loud can leave people unprotected and may breach the Alberta Fire Code. Call us and we will arrange proper isolation and restoration.

Common deficiencies we fix

Annual inspection reports often list the same handful of problems. Most are straightforward to fix, but they need to be cleared promptly and documented.

  • Detectors that are dirty, painted over or past their service life.
  • Rooms created during renovations with no detection or with horns that cannot be heard.
  • Ground faults and trouble signals from damaged or wet wiring.
  • Standby batteries that no longer hold their charge.
  • Door holders, dampers or air handler shutdowns that do not respond to an alarm.

We trace the cause, repair or replace the affected parts, and test them so the deficiency can be signed off. If a recurring trouble keeps coming back, we look for the root cause, such as moisture in an exterior junction box or a cable damaged by another trade, rather than clearing it again and again.

After handover

Once a system is verified, the owner is responsible for keeping it in service, including periodic inspection and testing by qualified people. Keep your verification report, as-built drawings and annual inspection records together, because inspectors and insurers will ask for them.

Cost on fire alarm projects is driven by building size, device count, ceiling access, whether the existing panel can be extended, and how much work must happen while the building stays occupied.

If you are buying or leasing a building, ask for the latest fire alarm inspection report before you sign. Outstanding deficiencies or an obsolete panel can be a significant cost to plan for.

Questions we hear

Can my existing panel be extended?

Often, if it is still supported and has capacity. Older panels with no available parts are usually better replaced. We assess yours and explain the options.

Do you do annual inspections?

We can coordinate annual inspection and testing and fix the deficiencies found, so the work and paperwork stay in one place.

Do homes need a fire alarm system?

Single-family homes use interconnected smoke alarms rather than a fire alarm panel. We install and replace hardwired smoke and CO alarms as part of residential work.

Will the building stay protected during work?

We plan the sequence to keep protection active, and arrange fire watch or notifications where the authority requires it.

How this job runs

What to expect

  1. Assess

    We review the drawings, occupancy and existing system, and identify what the code and authority will require.

  2. Plan and permit

    Device layouts and riser drawings are prepared, and permits and reviews are arranged.

  3. Install

    Circuits, devices and the panel are installed while keeping existing protection active wherever possible.

  4. Verify and hand over

    Every device is tested and verified, deficiencies are cleared, and you receive the documents for your records.

Related

More in Security and low voltage

Service

Security and low voltage

Alberta Electrical designs and installs access control, video surveillance, fire alarm systems and structured cabling for Edmonton businesses, facilities and homes.

View service →
Security and low voltage

Access control systems

Card, fob, keypad and mobile access control for Edmonton offices, shops, industrial sites and multi-family buildings, installed and wired by licensed electricians.

View service →
Security and low voltage

Video surveillance

IP camera systems for Edmonton businesses, industrial yards and homes: coverage planning, PoE cabling, recorders, remote viewing and backup power.

View service →
Security and low voltage

Structured cabling

Cat 6, Cat 6A and fibre cabling for Edmonton offices, warehouses, industrial sites and homes, with racks, labelling and certification testing.

View service →

Guides

Read before you book

All guides →

Ready to book fire alarm systems?

Call the 24/7 line or send a request and we'll set up a consultation and a free estimate.