Help people find the way out when the power fails.

CommercialIndustrialResidential

Emergency and exit lighting in Edmonton: installation, upgrades to pictogram exit signs, battery units and remote heads, and testing with records for fire inspections.

Why it matters

When the power fails in a building, whether from a storm, a fault or a fire, people still need to find their way out. Emergency lighting lights the path; exit signs show the direction. Both are required in most commercial, industrial and multi-unit residential buildings.

We install, upgrade, test and repair emergency and exit lighting for offices, shops, restaurants, warehouses, plants and apartment buildings around Edmonton.

FIG 01Alberta Electrical
Floor plan of offices along a corridor with a dashed orange egress path leading to the exit, yellow remote heads, a battery unit with two heads, and orange exit signs at the change of direction and the exit door.Emergency lighting along the path to the exitCORRIDOROFFICEOFFICESTORAGELOBBYEXITBattery unit with two headsRemote headExit sign along path
Emergency heads and exit signs light the corridor and show the route to the exit when normal power fails.

What the code requires

Emergency lighting and exit signs are governed by the Alberta Building Code, which sets where they are needed, and the Alberta Fire Code, which sets how they are maintained and tested. The electrical installation follows the Canadian Electrical Code.

In general, emergency lighting must light exits, corridors and other paths people use to leave, and must run on battery or another backup source for a set time when normal power fails. Exit signs must be visible along the path and at changes in direction. The exact requirements depend on building type, occupancy and when the building was built or renovated, so we check them for your building.

Good to knowPictogram exit signs

Newer Canadian codes call for the green running-figure exit sign instead of the old red EXIT sign. Whether existing signs must be changed depends on your building and any renovation work, which we can confirm.

Equipment we install

FIG 02Alberta Electrical
Drawing of an orange running-figure exit sign with an arrow, and a battery unit with two yellow heads, a battery and a test button, above a note about regular push-to-test and duration tests.Exit sign and battery unit essentialsrunning figurePictogram sign with arrow(current Canadian style)batterytestBattery unit with headsRegular checks: push-to-test, status light, aiming, and a longerduration test. Intervals are set by the fire code; keep records.
A pictogram exit sign and a battery unit with lamp heads, along with the checks required to keep them working.
  • Battery units with built-in heads for corridors, stairwells and open areas.
  • Remote heads powered by a central battery unit, to light more area from one battery.
  • Combination units with an exit sign and heads in one.
  • Exit signs with self-diagnostics that flag faults automatically.
  • Units rated for cold or damp locations like warehouses and parkades.

In buildings with a generator, some emergency lighting may be powered from the generator instead. See emergency and backup power.

Testing and records

Emergency lighting only helps if it works when needed. Batteries age, lamps fail and units get knocked out of aim. The Fire Code requires regular inspection and testing, typically including frequent quick checks and a longer annual test that runs the units on battery for their full rated time. The exact intervals and records depend on your building, and a fire inspector may ask to see them.

We can take care of testing on a schedule, replace failed batteries and lamps, and keep records in our online job management system. This fits well into a commercial maintenance plan.

TipQuick check you can do

Press the test button on a unit: the heads should light. If they do not, or a status light shows a fault, call us. Do not open the unit.

Cost

Cost depends on the number of units and signs, ceiling heights, whether new circuits are needed, the type of equipment and how many locations need upgrading. Testing programs are priced by the number of units and the visit frequency.

Common problems we find on first visits include units with dead batteries, heads aimed at the ceiling after renovations, exit signs hidden behind new signage or shelving, and areas that were added or reconfigured without updating the emergency lighting. Any time you renovate or change a layout, it is worth checking that the emergency lighting still covers the new path out.

Questions we hear

How long should emergency lights stay on?

The required duration depends on the building and code edition. We confirm the requirement for your building and test against it.

Do I have to replace red EXIT signs?

Not always. Newer codes call for pictogram signs, but existing signs may be allowed to remain in some buildings unless there is a renovation. We can check for yours.

How often do batteries need replacing?

It depends on the battery type, temperature and use. Testing shows when a battery can no longer hold the rated time.

How this job runs

What to expect

  1. Survey

    We walk the building, map egress paths, and check existing units, signs and records.

  2. Recommend

    We identify gaps and failed units, and quote repairs or upgrades.

  3. Install or repair

    We install units and signs, replace batteries and lamps, and aim heads along the path.

  4. Test and record

    We test each unit and record the results for your fire inspection file.

Related

More in Lighting

Guides

Read before you book

All guides →
Lighting · 8 min

Emergency and exit lighting: requirements, testing and upkeep

What emergency and exit lighting must do, the types of systems used in Alberta buildings, how testing and record keeping work, and the deficiencies inspectors find most often.

Read the guide →
Backup power and security · 7 min

Fire alarm systems: the basics and what annual inspections involve

How a commercial fire alarm system works, what owners are responsible for under Alberta's fire code, and what to expect when the system is inspected and tested.

Read the guide →
Lighting · 7 min

Pot light layout: spacing, placement and insulated ceilings

How to lay out pot lights so a room is evenly lit, where to put them in kitchens, halls and bathrooms, and what an Edmonton attic ceiling means for the fixtures you choose.

Read the guide →

Ready to book emergency and exit lighting?

Call the 24/7 line or send a request and we'll set up a consultation and a free estimate.

Call 24/7Request service