Controls and automation

Controls migration

Move off obsolete PLCs, relay logic and old SCADA without losing what your system knows.

CommercialIndustrial

Planned migration from obsolete PLCs, relay panels, legacy HMIs and SCADA to supported platforms, with short cutovers and full documentation, for facilities across Alberta and BC.

When old controls become a risk

Many Alberta plants and municipal systems still run on PLCs and HMIs that were installed decades ago. They have worked well, but spare parts are scarce, programming software needs an old laptop, and the person who wrote the program has retired. The system is fine until the day a processor fails and there is no replacement.

  • The manufacturer no longer supports the hardware
  • Spare parts come only from the used market
  • Programming needs software that runs only on old computers
  • Nobody has a current, documented backup
  • Relay logic is hard to change and harder to troubleshoot
  • HMI or SCADA runs on an unsupported operating system

A planned migration costs less, in money and stress, than an emergency replacement during a breakdown. The aim is to move to a supported platform while keeping everything the old system did right.

Keep what works, replace what does not

Most of the value in a control system is in the field: instruments, valves, motors and the cable that connects them. In most migrations that stays. We replace the processor, I/O and screens, and often reuse the existing field terminals with new wiring harnesses so field wiring is not disturbed.

FIG 01Alberta Electrical
Left, an old PLC rack in grey above its terminal strip; right, a new PLC with orange I/O modules connected by orange harness lines to the same terminal strip, with a note that field devices stay and every loop is re-checked.Migration: keep field wiring, replace the brainBEFOREobsolete PLC, no sparesAFTERcurrent PLC, supportedexisting terminalssame terminals, new harnessfield devices and cable stay; I/O is re-mapped and every loop re-checked
Before and after a PLC migration: the obsolete controller and I/O are replaced with a supported platform, while the existing field terminals and wiring are reused through new harnesses.

Converting the program is more than translation. Automatic conversion tools help, but we review the logic, fix known problems, remove dead code and add the comments the original never had, while making sure the process behaves the way operators expect.

Old I/ONew I/OTagChecked
Rack 1, slot 3, pt 0Slot 4, ch 0LT_101Loop check after cutover
Rack 1, slot 5, pt 7Slot 6, ch 7P101_RUNFunction test with ops

Planning the cutover

The hardest part of a migration is the switch-over. We do as much as possible before the shutdown: audit, convert, simulate and factory test the new system with the plant still running on the old one. That leaves only the physical cutover and verification for the outage window.

FIG 02Alberta Electrical
Timeline with five stages: audit, convert, test offline, a tall orange cutover block during the shutdown, and verify; a dashed line shows the plant running on the old system for the first three stages.A phased migration plan1 Auditback up, document2 Convertcode, screens, I/O3 Test offlinesimulate, FAT4 Cutovershutdown5 Verifyre-loopplant keeps running on the old systemplanned outage windowRollback plan: old processor and wiring kept ready untilthe new system is proven in operation.
A phased migration: auditing, converting and testing happen while the plant keeps running on the old system, so only the cutover and verification fall inside the planned outage.

Large systems can be migrated in stages, one area or one panel at a time, with temporary communication links between old and new. That spreads the risk and fits around production.

Good to knowAlways have a way back

Until the new system is proven, keep the old processor, program and wiring in a state where you could return to them. A rollback plan turns an unexpected problem into a delay instead of a crisis.

Making the business case

A migration is easier to approve when the risk is clear. We help you set out what the current system controls, what an unplanned failure would cost in downtime, how available spare parts really are and what a planned migration involves.

Not every system needs replacing at once. Sometimes the right first step is a full backup and documentation, a stock of critical spares, and a migration plan ready to go. We will tell you honestly which approach makes sense for your site.

  • Inventory of hardware and support status
  • Critical spares and failure impact
  • Options with phasing and outage needs
  • A plain-language summary for decision makers

Relay logic and old SCADA

Some systems still run on relays and timers. Replacing relay logic with a PLC makes changes easier and gives operators better diagnostics, but every hidden interlock in the old wiring must be found and carried over. We trace the existing circuits, document them and confirm the new logic does the same.

Old SCADA and HMI systems can be migrated the same way, preserving tag names, alarm history where possible and screen layouts that operators know. Our SCADA and remote monitoring team handles this. Migrations often go hand in hand with new control panels and plant retrofits, and we can deliver them together.

Questions we hear

Can we migrate without a long shutdown?

Often, yes. Doing the conversion and testing beforehand, reusing field wiring and staging the work can keep the outage short. How short depends on the size and design of the system.

Do we have to change PLC brands?

No. Many migrations move to the current generation from the same manufacturer. We recommend based on support, spares and your team's familiarity, not on any partnership.

What if we do not have the original program?

If the processor is still running, we can usually upload the logic. If not, we rebuild it from drawings, field tracing and the control narrative.

Will our operators need retraining?

Some. We keep screens familiar where possible and train operators and maintenance on what has changed before and after cutover.

How this job runs

What to expect

  1. Audit and assess

    We back up programs, inventory hardware and drawings, and set out the risks and options in plain language.

  2. Convert and test

    Programs, screens and I/O maps are converted, reviewed and tested offline while you keep running.

  3. Cut over

    In the planned outage, we swap hardware, connect harnesses and bring the new system online.

  4. Verify and hand over

    Every loop and function is re-checked, then drawings, backups and training are delivered.

Related

More in Controls and automation

Service

Controls and automation

Industrial controls and automation across Alberta and British Columbia: PLC systems, custom control panels, SCADA and remote monitoring, and migrations off obsolete control platforms.

View service →
Controls and automation

PLC systems

PLC and HMI programming, modifications, troubleshooting and support for industrial and municipal systems across Alberta and BC, with commented code and current backups.

View service →
Controls and automation

Control panels

Design, build, installation and modification of industrial control panels for pumps, machines and processes in Alberta and British Columbia, with approval and full documentation.

View service →
Controls and automation

SCADA and remote monitoring

SCADA, telemetry and remote monitoring for pump stations, lift stations, reservoirs, well sites and plants across Alberta and BC, with secure communications and alarm callout.

View service →

Guides

Read before you book

All guides →
Instrumentation, controls and automation · 6 min

What a loop check is and why it matters

A loop check proves that each instrument and control signal is wired, configured and displayed correctly from the field device to the operator screen. Here is what it involves and when you need one.

Read the guide →
Instrumentation, controls and automation · 7 min

PLC basics for owners and facility managers

What a programmable logic controller does, what to keep on file, and the questions that protect you when a PLC runs your process, pumps or equipment.

Read the guide →
Instrumentation, controls and automation · 8 min

Migrating obsolete PLCs without a long shutdown

How to tell when your PLC hardware is becoming a risk, the main migration approaches, and how to plan a cutover that keeps the outage short.

Read the guide →