3400, 10180 101 St NW, Edmonton, AB T5J 3S424/7 service 1 (800) 716-8955
  1. Home
  2. Services
  3. Controls and automation
  4. PLC systems

Controls and automation

PLC systems

Programming, changes and troubleshooting for the controllers that run your equipment.

CommercialIndustrial

PLC and HMI programming, modifications, troubleshooting and support for industrial and municipal systems across Alberta and BC, with commented code and current backups.

What a PLC does for you

A programmable logic controller is an industrial computer built to run the same logic reliably for years. It reads switches and transmitters, decides what should happen, and turns motors, valves and alarms on and off. It replaced walls of relays and timers, and it is the heart of most automated equipment in Alberta plants and facilities.

We work with PLCs and HMIs from major manufacturers, on everything from a single pump skid to multi-panel process systems. Our controls specialists work alongside our licensed journeyperson electricians and instrument technicians, so a program change that needs new wiring or a new transmitter is handled in one job.

FIG 01Alberta Electrical
Row of PLC modules: power supply, CPU, 16-channel digital input, 16-channel digital output, 8-channel analog input highlighted orange, 4-channel analog output and Ethernet, with leaders to the switches, starters, transmitters and drives they connect to.A typical PLC rack and what it connects toPSCPUDI16 chDO16 chAI8 chAO4 chENETDI: switches, pushbuttons, aux contactsDO: starters, solenoids, lampsAI: 4-20 mA transmittersAO: drive speed, valvesHMIdrives
A PLC rack with power supply, processor, discrete and analog input and output modules and an Ethernet module, labelled with the field devices each one connects to.

Programming that the next person can read

A program that only its author understands is a liability. We write logic in clear, consistent structures, name tags so they match the drawings, and comment every rung or block that is not obvious. Ladder logic is still the most common language because electricians and technicians can follow it; we also use function block and structured text where they suit the task.

FIG 02Alberta Electrical
Ladder diagram between two vertical rails: rung 000 has a normally closed stop contact, a start contact with an orange seal-in branch, an overload contact and the M_RUN coil; rung 001 uses M_RUN and a normally closed low-level contact to drive PUMP_CMD.Ladder logic: motor start / stop with seal-in000001STOP_PBSTART_PBM_RUNMTR_OLM_RUNM_RUNLOW_LEVELPUMP_CMDOrange branch: the seal-in keeps the motor running after START is released.A slash marks a normally closed contact.
Two rungs of ladder logic: a start/stop circuit with a seal-in contact and overload, and a pump command that drops out on low level.
  • Control narrative first: we agree on what the system should do, in plain language, before writing code.
  • Consistent alarms: every alarm has a clear message, a priority and a defined response.
  • Safe defaults: outputs go to a safe state on fault, power loss or communication failure.
  • Testing before site: logic is simulated and reviewed before it touches your equipment.

Changes, additions and troubleshooting

Most of our PLC work is on systems that already exist: adding a pump, changing a sequence, adding alarms or fixing a fault that has bothered operators for months. Before changing anything, we take a backup of the running program and confirm it matches what is in your files.

Online edits can be made to some running systems, but only when the change is understood, tested and agreed with operations. Larger changes are made offline and downloaded during a planned stop.

SafetyKeep emergency stops hard-wired

Emergency stop and safety functions should follow your engineer's safety design, which normally means safety-rated devices and circuits rather than standard PLC logic alone. Never use a standard PLC program change to bypass a safety device.

Where PLCs fit

PLCs run all kinds of equipment across Alberta and BC. Typical systems we work on include:

  • Water and wastewater pumping, treatment and lift stations
  • Conveyors, packaging and material handling
  • Compressors, process skids and pumping in oil and gas
  • Grain handling, feed mills and agricultural processing
  • Building systems where a BAS is not the right fit

Small machines may use a compact controller or smart relay, while larger processes use modular PLCs with remote I/O over industrial Ethernet. We size the system to the job and leave room for expansion.

Backups, documentation and support

Every job ends with a current, commented program backup, updated I/O lists and marked-up drawings in our online job management system. If a processor fails at 3 a.m., that backup is what gets you running again.

When something stops working, our 24/7 line at 1 (800) 716-8955 connects you with someone who can help. Many problems turn out to be a failed field device rather than the PLC, so we troubleshoot from the I/O status outward and look at field instruments and motor controls as well. If your platform is near the end of its supported life, see controls migration.

Questions we hear

Can you work with an old PLC we cannot get parts for?

Often, yes, as long as we can still connect to it and back it up. We will also tell you honestly if it is time to plan a migration before a failure forces one.

We do not have the source program. Can you help?

Many PLCs let us upload the running logic, but comments and tag descriptions may be lost. We can upload it, rebuild the documentation and store a proper backup.

Do you do remote support?

Where your site allows secure remote access, some troubleshooting and changes can be done remotely. Any remote connection must follow your IT and cybersecurity rules.

Can you add HMI screens to an existing system?

Yes. We build or update HMI screens that match your existing standards and tag names so operators are not confused by a mix of styles.

How this job runs

What to expect

  1. Back up and review

    We back up the existing program, review drawings and talk with operators about what needs to change.

  2. Write the narrative

    Changes are written in plain language and agreed before any code is written.

  3. Program and test

    Logic and screens are developed and tested offline or in simulation where possible.

  4. Download and commission

    Changes go in during a planned window, are tested with operations, and backups and drawings are updated.

Related

More in Controls and automation

Service

Controls and automation

Industrial controls and automation across Alberta and British Columbia: PLC systems, custom control panels, SCADA and remote monitoring, and migrations off obsolete control platforms.

View service →
Controls and automation

Control panels

Design, build, installation and modification of industrial control panels for pumps, machines and processes in Alberta and British Columbia, with approval and full documentation.

View service →
Controls and automation

SCADA and remote monitoring

SCADA, telemetry and remote monitoring for pump stations, lift stations, reservoirs, well sites and plants across Alberta and BC, with secure communications and alarm callout.

View service →
Controls and automation

Controls migration

Planned migration from obsolete PLCs, relay panels, legacy HMIs and SCADA to supported platforms, with short cutovers and full documentation, for facilities across Alberta and BC.

View service →

Guides

Read before you book

All guides →

Ready to book plc systems?

Call the 24/7 line or send a request and we'll set up a consultation and a free estimate.

Call 24/7Request service