Transmitters, switches and analyzers installed so they read right on day one and keep reading right in January.

CommercialIndustrial

Installation of pressure, level, flow and temperature instruments, analyzers and valve instrumentation, with tubing, wiring and documentation, for plants and facilities across Alberta and BC.

The right instrument, installed the right way

Most instrument problems we are called to fix are installation problems. Impulse lines sloped the wrong way trap air or liquid. A transmitter mounted above a steam line cooks. A radar level gauge is aimed at a fill stream. The instrument is fine; the install is not.

Our instrument technicians install field devices to the manufacturer's requirements and your project specifications, and they ask questions when something on the drawing will not work in the field. Our licensed journeyperson electricians run the cable, tray and conduit that bring the signals home.

  • Pressure and differential pressure: gauge, absolute and DP transmitters, including flow across orifice plates and level in pressurized vessels.
  • Level: radar, guided wave, ultrasonic, DP and float or displacer types.
  • Flow: magnetic, Coriolis, vortex, ultrasonic and DP flow meters.
  • Temperature: RTDs and thermocouples in thermowells, with head-mount or remote transmitters.
  • Final elements: valve positioners, limit switches and solenoids on control and on/off valves.
FIG 01Alberta Electrical
Pipe with an orifice plate; two impulse lines drop from taps on either side through root valves into a heated enclosure (dashed orange) holding a manifold and DP transmitter on a pipe stand, with conduit and a seal running to a junction box.Typical DP transmitter installationorifice plateDPJB3-valve manifoldtransmitterpipe standheat-traced impulse linesheated, insulated enclosureseal where requiredroot valves
A differential pressure transmitter measuring flow across an orifice plate, with root valves, heat-traced impulse lines, a three-valve manifold, a heated enclosure and conduit to a junction box.

How the signal gets home

Most field instruments still talk over a 4-20 mA loop, often with a digital HART signal riding on top. Two wires carry both the power to the instrument and the measurement back to the control system. Many newer sites also use fieldbus or Ethernet-based instruments, and we install those to the network design.

FIG 02Alberta Electrical
A field transmitter wired through junction box JB-1 and a home-run cable to an analog input card with a 24 VDC supply and input resistor; below, a scale shows 4 mA as 0 percent, 12 mA as 50 percent and 20 mA as 100 percent.Two-wire 4-20 mA loopFIELDCONTROL ROOMtransmitterPT-101JB-1home-run cableAnalog input card24 VDCinput resistorloop current0%50%100%4 mA12 mA20 mAReadings outside 4 to 20 mA can flag a fault, not a process value.
A two-wire 4-20 mA loop: the transmitter draws power and sends its signal on the same pair, through a junction box to an analog input card in the control room.

We use shielded, twisted-pair instrument cable, land shields at one end only unless the design says otherwise, and keep instrument cable separated from power cable. Junction boxes are labelled to match the loop drawings so the next person can follow a signal without guessing.

Hazardous locations and harsh conditions

Instruments often sit in areas classified as hazardous because of flammable gas, vapour or dust. In those areas the instrument, the enclosure and the wiring method all need to suit the classification. That may mean explosion-proof housings with conduit seals, or intrinsically safe circuits with approved barriers and careful separation.

We confirm the classification drawings before installing, and we check that each device carries a certification marking suitable for that location under the Canadian Electrical Code as adopted in the province where we are working.

TipPlan for winter at the design stage

In Alberta and northern BC, outdoor instruments with wet impulse lines usually need heat tracing and insulated enclosures. It is far cheaper to plan for this up front than to chase frozen readings after start-up. See our process heat tracing work.

Documentation you can use

An instrument is only as maintainable as its records. For every device we install, we record the tag, make, model, serial number, range and configuration, and we photograph the installation. Loop drawings and junction box layouts are marked up wherever the field differs from the design.

Those records land in our online job management system and feed straight into your instrument index. When a technician comes back in five years to replace a transmitter, the information is already there.

  • Instrument data and configuration records
  • Installation photos
  • Marked-up loop and wiring drawings
  • Calibration and loop check results

Replacing and upgrading existing instruments

On operating facilities, much of our work is one-for-one replacement of failed or obsolete instruments. We check that the new device's range, process connection, materials and output match the old one, update the configuration, then calibrate and loop check before returning it to service.

When an upgrade changes the signal type or adds diagnostics, we coordinate the change with whoever looks after your PLC systems so the control logic and screens are updated at the same time.

Questions we hear

Can you supply the instruments or install ones we buy?

Either. We can quote supply and install, or install owner-supplied instruments. In both cases we check the data sheet against the process before installation.

Do you set up HART and smart transmitters?

Yes. We configure range, units, damping and tags with a communicator or software, and record the settings in the handover package.

Can you work during a live operation?

Some installs can be done with the process running, such as hot-tapped connections or replacing a transmitter behind an isolation manifold. Whether that is safe depends on the process, and it is always done under your site's permit system.

Do you handle instrument wiring in hazardous areas?

Yes. We follow the hazardous location rules of the Canadian Electrical Code as adopted in the province and use certified equipment and wiring methods for the area classification.

How this job runs

What to expect

  1. Survey and review

    We walk the site with your P&IDs, instrument index and data sheets, and check access, process connections and classification.

  2. Prepare materials

    We confirm models, ranges and certifications, pre-configure transmitters, and stage tubing, stands and cable.

  3. Install

    Instrument technicians mount and tube the devices while electricians pull and terminate cable, all under your site permits.

  4. Calibrate and loop check

    Each device is verified and loop checked, and the records and marked-up drawings go into our online job system.

Related

More in Instrumentation

Service

Instrumentation

Instrumentation services across Alberta and British Columbia: installing field instruments, calibrating them, loop checking and commissioning, and fixed gas detection, with records your team can trust.

View service →
Instrumentation

Instrument calibration

Bench and in-place calibration of pressure, temperature, level and flow instruments, with as-found and as-left records, for facilities across Alberta and British Columbia.

View service →
Instrumentation

Loop checks and commissioning

Instrument loop checks, function testing and commissioning support for new plants, expansions and control upgrades in Alberta and British Columbia, with signed loop sheets and a clean punch list.

View service →
Instrumentation

Gas detection

Fixed toxic and combustible gas detection systems for plants, parkades, mechanical rooms, shops and facilities in Alberta and BC: installation, wiring, controller setup, testing and maintenance.

View service →

Guides

Read before you book

All guides →

Ready to book field instrumentation?

Call the 24/7 line or send a request and we'll set up a consultation and a free estimate.

Call 24/7Request service