- Home
- Services
- Instrumentation
- Gas detection
Instrumentation
Gas detection
Fixed gas detection that sees a leak early, sounds the alarm and starts the right response.
Fixed toxic and combustible gas detection systems for plants, parkades, mechanical rooms, shops and facilities in Alberta and BC: installation, wiring, controller setup, testing and maintenance.
Where fixed gas detection is needed
Gas leaks are invisible and often odourless at dangerous levels. Fixed detectors watch the air continuously and can start ventilation, shut off a supply or tell people to leave before anyone is hurt. They do not replace personal monitors, but they protect a space around the clock.
- Oil and gas facilities, compressor buildings and wellsite shacks
- Water and wastewater plants, lift stations and wet wells
- Underground parkades and vehicle maintenance shops
- Boiler rooms and mechanical rooms with gas-fired equipment
- Refrigeration machine rooms and ice rinks
- Labs, battery rooms and process areas
Whether detection is required, and of which gases, depends on the building code, the Alberta OHS Code or WorkSafeBC requirements, your industry's standards and your own hazard assessment. We work from your engineer's design or help you assemble the information they need.
Choosing and placing detectors
Each gas behaves differently. Gases lighter than air, such as natural gas, collect near the ceiling. Heavier ones, like hydrogen sulphide and propane, sink and pool in low spots and pits. Others are sensed near the breathing zone. Placement also depends on where leaks are likely, how air moves and where people work.
We check sensor type, range and certification for the area. In a classified hazardous location the detector and its wiring must be certified for that classification, and we wire it to the hazardous location rules of the Canadian Electrical Code.
Alarms, actions and integration
A detector is only useful if something happens when it alarms. Most systems use at least two alarm levels plus a fault alarm, each tied to a clear action. Setpoints are set from the gas, your hazard assessment and the rules that apply, not chosen on the day of installation.
Controllers can start exhaust fans, close gas valves, flash strobes at entrances and send alarms to a PLC, a building automation system or a SCADA system for remote callout. Where a detection system must interface with a fire alarm system, we coordinate with the fire alarm designer.
Do not try to find the leak or reset the alarm. Get everyone out, follow your site's emergency plan, and call the gas utility or emergency services as appropriate. Re-entry should be decided by trained people using portable monitors.
Parkades and mechanical rooms
Not every gas detection system is in a plant. Many Edmonton parkades use carbon monoxide or nitrogen dioxide sensing to run exhaust fans only when vehicle exhaust builds up, instead of all day. Boiler and mechanical rooms may have detection for natural gas or carbon monoxide, and refrigeration machine rooms for the refrigerant in use.
These systems still need the right detector types, sensible placement and regular testing. When they are tied into a building automation system, the BAS can trend readings, run fans and send alarms to building staff after hours.
Testing and maintenance
Gas sensors drift and eventually wear out, and some can be poisoned by other chemicals in the air. Regular bump testing confirms each detector responds to gas, and periodic calibration with certified test gas brings it back into tolerance. Intervals follow the manufacturer's instructions and any rules that apply to your site.
Our instrument technicians test, calibrate and replace sensors, and every visit is recorded in our online job management system with the detector tag, test gas used and result. If a detector fails between visits, our 24/7 line at 1 (800) 716-8955 can get someone on the way.
Questions we hear
Is this the same as a home CO alarm?
No. Home carbon monoxide alarms are self-contained devices covered by residential rules. This service is fixed detection systems for commercial and industrial spaces, wired to controllers and other systems.
What alarm setpoints should we use?
That depends on the gas, your hazard assessment and the occupational health and safety rules that apply. Your engineer or safety advisor should set them, and we can supply the information they need.
How often do detectors need testing?
Follow the manufacturer's instructions and any requirements for your site. Many sites bump test frequently and calibrate on a set schedule, and we can track both for you.
Can the system call someone after hours?
Yes. Alarms can be sent through a PLC, building automation or SCADA system to phones, or to a monitoring service, so an alarm at night does not go unnoticed.
How this job runs
What to expect
Assess the space
We review the gases, the hazard assessment, the design and any classification drawings, and walk the space.
Confirm the design
Detector types, locations, setpoints and actions are confirmed with your engineer or safety lead, and permits are arranged.
Install and wire
We install detectors, controllers, alarms and interlocks with certified equipment and the right wiring methods.
Commission and maintain
Each detector is tested with certified gas, actions are proven, and we set up a bump test and calibration schedule.
Related
More in Instrumentation
Instrumentation
Instrumentation services across Alberta and British Columbia: installing field instruments, calibrating them, loop checking and commissioning, and fixed gas detection, with records your team can trust.
View service →InstrumentationField instrumentation
Installation of pressure, level, flow and temperature instruments, analyzers and valve instrumentation, with tubing, wiring and documentation, for plants and facilities across Alberta and BC.
View service →InstrumentationInstrument calibration
Bench and in-place calibration of pressure, temperature, level and flow instruments, with as-found and as-left records, for facilities across Alberta and British Columbia.
View service →InstrumentationLoop checks and commissioning
Instrument loop checks, function testing and commissioning support for new plants, expansions and control upgrades in Alberta and British Columbia, with signed loop sheets and a clean punch list.
View service →Guides
Read before you book
How to set instrument calibration schedules
A practical approach to deciding how often each instrument gets calibrated, what a good calibration record contains, and how to adjust intervals using your own data.
Read the guide →Instrumentation, controls and automation · 8 minHazardous locations basics for shops and plants
What makes an area a hazardous location, how Zones and Divisions work, the common ways electrical equipment is protected, and what owners are responsible for.
Read the guide →Instrumentation, controls and automation · 7 minGas detection in shops, parkades and plants
How fixed gas detection works, which sensor types suit which gases, where sensors go, and how to keep a system you can trust.
Read the guide →Ready to book gas detection?
Call the 24/7 line or send a request and we'll set up a consultation and a free estimate.