Instrumentation

Gas detection

Fixed gas detection that sees a leak early, sounds the alarm and starts the right response.

CommercialIndustrial

Fixed toxic and combustible gas detection systems for plants, parkades, mechanical rooms, shops and facilities in Alberta and BC: installation, wiring, controller setup, testing and maintenance.

Where fixed gas detection is needed

Gas leaks are invisible and often odourless at dangerous levels. Fixed detectors watch the air continuously and can start ventilation, shut off a supply or tell people to leave before anyone is hurt. They do not replace personal monitors, but they protect a space around the clock.

  • Oil and gas facilities, compressor buildings and wellsite shacks
  • Water and wastewater plants, lift stations and wet wells
  • Underground parkades and vehicle maintenance shops
  • Boiler rooms and mechanical rooms with gas-fired equipment
  • Refrigeration machine rooms and ice rinks
  • Labs, battery rooms and process areas

Whether detection is required, and of which gases, depends on the building code, the Alberta OHS Code or WorkSafeBC requirements, your industry's standards and your own hazard assessment. We work from your engineer's design or help you assemble the information they need.

Choosing and placing detectors

Each gas behaves differently. Gases lighter than air, such as natural gas, collect near the ceiling. Heavier ones, like hydrogen sulphide and propane, sink and pool in low spots and pits. Others are sensed near the breathing zone. Placement also depends on where leaks are likely, how air moves and where people work.

FIG 01Alberta Electrical
Room cross-section with orange detectors near the ceiling for natural gas, near the floor for hydrogen sulphide or propane and at mid height in the breathing zone, wired to a controller outside that drives a horn and strobe and an exhaust fan.Detector height depends on the gasequipmentlighter than aire.g. natural gasbreathing zoneheavier than aire.g. H2S, propanegas detectioncontrollerhorn / strobeexhaust fanMount height and spacing follow the gas, the design and the maker's instructions.
Section of a room showing that detectors for lighter-than-air gases go high, heavier-than-air gases go low, and some gases are sensed near the breathing zone, all wired to a controller that drives alarms and ventilation.

We check sensor type, range and certification for the area. In a classified hazardous location the detector and its wiring must be certified for that classification, and we wire it to the hazardous location rules of the Canadian Electrical Code.

Alarms, actions and integration

A detector is only useful if something happens when it alarms. Most systems use at least two alarm levels plus a fault alarm, each tied to a clear action. Setpoints are set from the gas, your hazard assessment and the rules that apply, not chosen on the day of installation.

FIG 02Alberta Electrical
A detector feeds a controller which branches to three outcomes: a yellow low alarm that warns and starts ventilation, an orange high alarm that triggers evacuation and gas shut-off, and a fault alarm for sensor or wiring problems.Typical alarm and action logicdetectorreadingcontrollercomparesLOW ALARMwarn, start ventilation, notifyHIGH ALARMevacuate, shut off gas supplyFAULTsensor or wiring problem, callSetpoints come from the gas, the hazard assessment and applicable rules.Latching alarms need a person to reset them after the cause is cleared.
How a fixed gas detection system typically responds: the controller compares each detector reading to low and high alarm setpoints and also reports sensor faults, each with its own action.

Controllers can start exhaust fans, close gas valves, flash strobes at entrances and send alarms to a PLC, a building automation system or a SCADA system for remote callout. Where a detection system must interface with a fire alarm system, we coordinate with the fire alarm designer.

SafetyIf a gas alarm sounds, leave

Do not try to find the leak or reset the alarm. Get everyone out, follow your site's emergency plan, and call the gas utility or emergency services as appropriate. Re-entry should be decided by trained people using portable monitors.

Parkades and mechanical rooms

Not every gas detection system is in a plant. Many Edmonton parkades use carbon monoxide or nitrogen dioxide sensing to run exhaust fans only when vehicle exhaust builds up, instead of all day. Boiler and mechanical rooms may have detection for natural gas or carbon monoxide, and refrigeration machine rooms for the refrigerant in use.

These systems still need the right detector types, sensible placement and regular testing. When they are tied into a building automation system, the BAS can trend readings, run fans and send alarms to building staff after hours.

Testing and maintenance

Gas sensors drift and eventually wear out, and some can be poisoned by other chemicals in the air. Regular bump testing confirms each detector responds to gas, and periodic calibration with certified test gas brings it back into tolerance. Intervals follow the manufacturer's instructions and any rules that apply to your site.

Our instrument technicians test, calibrate and replace sensors, and every visit is recorded in our online job management system with the detector tag, test gas used and result. If a detector fails between visits, our 24/7 line at 1 (800) 716-8955 can get someone on the way.

Questions we hear

Is this the same as a home CO alarm?

No. Home carbon monoxide alarms are self-contained devices covered by residential rules. This service is fixed detection systems for commercial and industrial spaces, wired to controllers and other systems.

What alarm setpoints should we use?

That depends on the gas, your hazard assessment and the occupational health and safety rules that apply. Your engineer or safety advisor should set them, and we can supply the information they need.

How often do detectors need testing?

Follow the manufacturer's instructions and any requirements for your site. Many sites bump test frequently and calibrate on a set schedule, and we can track both for you.

Can the system call someone after hours?

Yes. Alarms can be sent through a PLC, building automation or SCADA system to phones, or to a monitoring service, so an alarm at night does not go unnoticed.

How this job runs

What to expect

  1. Assess the space

    We review the gases, the hazard assessment, the design and any classification drawings, and walk the space.

  2. Confirm the design

    Detector types, locations, setpoints and actions are confirmed with your engineer or safety lead, and permits are arranged.

  3. Install and wire

    We install detectors, controllers, alarms and interlocks with certified equipment and the right wiring methods.

  4. Commission and maintain

    Each detector is tested with certified gas, actions are proven, and we set up a bump test and calibration schedule.

Related

More in Instrumentation

Service

Instrumentation

Instrumentation services across Alberta and British Columbia: installing field instruments, calibrating them, loop checking and commissioning, and fixed gas detection, with records your team can trust.

View service →
Instrumentation

Field instrumentation

Installation of pressure, level, flow and temperature instruments, analyzers and valve instrumentation, with tubing, wiring and documentation, for plants and facilities across Alberta and BC.

View service →
Instrumentation

Instrument calibration

Bench and in-place calibration of pressure, temperature, level and flow instruments, with as-found and as-left records, for facilities across Alberta and British Columbia.

View service →
Instrumentation

Loop checks and commissioning

Instrument loop checks, function testing and commissioning support for new plants, expansions and control upgrades in Alberta and British Columbia, with signed loop sheets and a clean punch list.

View service →

Guides

Read before you book

All guides →
Instrumentation, controls and automation · 7 min

How to set instrument calibration schedules

A practical approach to deciding how often each instrument gets calibrated, what a good calibration record contains, and how to adjust intervals using your own data.

Read the guide →
Instrumentation, controls and automation · 8 min

Hazardous locations basics for shops and plants

What makes an area a hazardous location, how Zones and Divisions work, the common ways electrical equipment is protected, and what owners are responsible for.

Read the guide →
Instrumentation, controls and automation · 7 min

Gas detection in shops, parkades and plants

How fixed gas detection works, which sensor types suit which gases, where sensors go, and how to keep a system you can trust.

Read the guide →

Ready to book gas detection?

Call the 24/7 line or send a request and we'll set up a consultation and a free estimate.

Call 24/7Request service