Documented, traceable calibration so your readings, alarms and records stand up.

CommercialIndustrial

Bench and in-place calibration of pressure, temperature, level and flow instruments, with as-found and as-left records, for facilities across Alberta and British Columbia.

Why instruments need calibration

Every instrument drifts. Sensors age, process conditions take their toll, and electronics shift with temperature. A transmitter that read perfectly at installation may be reading a few percent off two years later, and nobody notices until a batch is off spec or a safety trip does not happen when it should.

Calibration compares an instrument against a reference of known accuracy, records how far off it was, adjusts it back into tolerance and records the result. Our instrument technicians do this with reference equipment that is itself calibrated and traceable to national standards.

  • Process quality and product consistency
  • Custody transfer or billing measurements, where other rules may also apply
  • Safety trips, interlocks and alarm setpoints
  • Environmental and regulatory reporting
  • Energy and utility metering inside a facility

How a calibration is done

For most transmitters we apply known inputs at several points across the range, usually zero, quarter, half, three-quarter and full scale, and read the output at each point. Going up and coming back down shows hysteresis as well as error.

FIG 01Alberta Electrical
A reference pressure source connected by hose to a transmitter, whose output pair runs in orange to a documenting calibrator; a HART communicator is clipped across the loop, with a yellow note to record as-found and as-left results.Pressure transmitter calibration setupreferencepressuresourcetest hosetransmitterunder testdocumentingcalibratorreads mA andpressureHARTcommunicatortraceable tonational standardsRecord as-found, adjust, record as-left
A typical bench or in-place calibration setup: a reference pressure source drives the transmitter while a documenting calibrator reads the output current and a HART communicator adjusts the settings.

The first set of readings is the as-found result. It tells you whether the instrument was in tolerance while it was in service, which matters if it controlled product or protected equipment. If it is out, we adjust it and repeat the check to produce the as-left result.

FIG 02Alberta Electrical
Graph of error versus input from 0 to 100 percent with a yellow tolerance band; orange as-found points rise above the upper limit at 75 and 100 percent, while dark as-left points lie flat near zero.As-found vs as-left, five-point check+ limit- limit00%25%50%75%100%input (% of calibrated range)error (% of span)as-found: driftedas-left: in tolerance
Calibration results plotted as error at five test points: the as-found readings drift outside the tolerance band at the top of the range, and the as-left readings sit near zero after adjustment.

Tolerances are set per instrument by your engineering or quality requirements, not by us. If you do not have them defined, we can help you set reasonable values based on how each instrument is used.

Bench or in place

Some instruments are easiest to calibrate in our shop or a site workshop, especially when several units can be swapped with spares. Others are better done in place, with the instrument isolated from the process and tested where it lives. We recommend the approach that keeps your downtime lowest.

ApproachWorks well for
BenchSpare rotation, temperature elements, gauges, small transmitters
In placeLarge or hard-to-remove devices, mounted flow meters, trip switches
Verification onlySmart devices with self-diagnostics, where full calibration is not due
SafetyIsolate before you test

Calibrating in place means isolating, venting and sometimes draining an instrument that may be connected to a hazardous process. That work belongs under your site's permit and lockout procedures, done by trained people.

When an instrument should be replaced instead

Sometimes calibration shows that an instrument is no longer worth keeping. If it drifts out of tolerance at every check, will not hold an adjustment, or has failing electronics, recalibrating it again only delays the problem.

We note these instruments on the report and suggest a suitable replacement, matched to the process and your site standards. Replacement can be done during the same visit when the part is available, followed by configuration, calibration and a loop check, so the new device goes back into service fully documented.

  • Repeated out-of-tolerance as-found results
  • Unstable or noisy output
  • Physical damage, corrosion or leaks
  • Obsolete models with no parts or support

Records and schedules

A calibration you cannot prove did not happen. Every check we do produces a record with the tag number, reference equipment used, as-found and as-left results, the technician and the date. Records are posted to our online job management system so you can find them during an audit.

We can also help build a calibration schedule. Critical safety instruments and instruments that drift quickly get checked more often; stable, low-impact ones less often. Intervals should come from your risk assessment and the instrument's history, so we review results over time and suggest adjustments.

Questions we hear

How often should instruments be calibrated?

It depends on how critical the measurement is, how stable the instrument is and any regulatory or quality requirements that apply. We help you set intervals from risk and history rather than one fixed number.

What happens if an instrument is found out of tolerance?

We record the as-found result, adjust it and record the as-left result. If it was significantly out, we flag it so you can assess the impact on product or safety during the time it was in service.

Can you calibrate safety system instruments?

Yes, as part of your proof-testing program. We follow your procedures for bypassing and restoring safety functions and record each step.

Do you calibrate gas detectors too?

Yes. Gas detectors need regular bump tests and calibrations with certified test gas. See our gas detection service.

How this job runs

What to expect

  1. Build the list

    We review your instrument index, tolerances and due dates, and agree on which instruments are in scope.

  2. Schedule around operations

    We plan bench swaps and in-place work to fit your production and shutdown windows.

  3. Calibrate

    Instrument technicians run as-found checks, adjust where needed and record as-left results with traceable equipment.

  4. Report and follow up

    Certificates go to our online job system, with notes on instruments that should be repaired or replaced.

Related

More in Instrumentation

Service

Instrumentation

Instrumentation services across Alberta and British Columbia: installing field instruments, calibrating them, loop checking and commissioning, and fixed gas detection, with records your team can trust.

View service →
Instrumentation

Field instrumentation

Installation of pressure, level, flow and temperature instruments, analyzers and valve instrumentation, with tubing, wiring and documentation, for plants and facilities across Alberta and BC.

View service →
Instrumentation

Loop checks and commissioning

Instrument loop checks, function testing and commissioning support for new plants, expansions and control upgrades in Alberta and British Columbia, with signed loop sheets and a clean punch list.

View service →
Instrumentation

Gas detection

Fixed toxic and combustible gas detection systems for plants, parkades, mechanical rooms, shops and facilities in Alberta and BC: installation, wiring, controller setup, testing and maintenance.

View service →

Guides

Read before you book

All guides →

Ready to book instrument calibration?

Call the 24/7 line or send a request and we'll set up a consultation and a free estimate.

Call 24/7Request service